Production information
Description
- Intriductionl:
- Features:
- Technical Specifications:
Measure Range: Refer to the range in the table
Accuracy: ≤±2% FS
Repeatability: ±1%FS
Response Time: 90% of FS reading ≤30 seconds
Stability:<±2%FS/7d
Sample Gas Pressure: 0.05MPa≤Inlet pressure≤0.2MPa
Sample Gas Flow: 200-400ml/min
Ambient Humidity:<90%RH
Ambient Temperature: 0℃~+45℃
Sample Gas Temperature: 5~45℃
Analogue Output: 4-20mA, 0-20mA, 0-1V, 0-5V,0-10V
Contact Capacity: AC125V 0.3A, AC 110V 0.5A DC24 3A
Sensor Life: 18000 hours (normal use)
Instrument life:>50000 hours (normal use)
Sensor Principle: Microprocessor thermal conductivity
Power Supply: 85~264VAC, 50/60Hz
Alarm Capacity: 240VAC, 0.2A
Instrument Dimension: 144(W) ×144(H) ×295(D) mm
Installation Method: Dial installation
- Applications:
- Intriductionl:
CI-TC90 thermal conductivity analyzer is a kind of intelligent analyzer based on microprocessor, considering microprocessor thermal conductivity sensor as measuring unit. It has high accuracy, good stability, comprehensive function and long service life. Applied to test the H2 or He in binary gas or binary mixture gas.
- Features:
- Automatic measurement
- Interference gas compensation function
- Menu lock function
- Touch the key technology
- Optical isolation protection
- Analogue output can be set freely
- Small size, simple structure and convenience in operation and maintenance
- Technical Specifications:
Measure Range: Refer to the range in the table
Accuracy: ≤±2% FS
Repeatability: ±1%FS
Response Time: 90% of FS reading ≤30 seconds
Stability:<±2%FS/7d
Sample Gas Pressure: 0.05MPa≤Inlet pressure≤0.2MPa
Sample Gas Flow: 200-400ml/min
Ambient Humidity:<90%RH
Ambient Temperature: 0℃~+45℃
Sample Gas Temperature: 5~45℃
Analogue Output: 4-20mA, 0-20mA, 0-1V, 0-5V,0-10V
Contact Capacity: AC125V 0.3A, AC 110V 0.5A DC24 3A
Sensor Life: 18000 hours (normal use)
Instrument life:>50000 hours (normal use)
Sensor Principle: Microprocessor thermal conductivity
Power Supply: 85~264VAC, 50/60Hz
Alarm Capacity: 240VAC, 0.2A
Instrument Dimension: 144(W) ×144(H) ×295(D) mm
Installation Method: Dial installation
Minimum Range | |
H2 | 0~1%(95~100%) |
He | 0~2% |
Ar | 0~10% |
CO2 | 0~20% |
CH4 | 0~15% |
H2 in blast furnace gas | 0~10% |
H2 in acid convertor gas | 0~20% |
H2 in wood gasification | 0~30% |
- Applications:
It can be used to in scrubbed gas monitoring, air separation; protective gas and H2 monitoring(0~25% of H2 in Ar), synthetic gas detection, gas manufacturing, chemical engineering application, wood gasification, blast furnace gas, acid converter gas and H2 cooling generator.
- Order Knowledge:
- Order Knowledge:
- Measure range
- Tested gas pressure & temperature
- Gas composition & impurities